思科MDS和N5K FC存储配置试验
normanhere
文章标签:
版权声明:本文为博主原创文章,遵循 CC 4.0 BY-SA 版权协议,转载请附上原文出处链接和本声明。 本文链接:https://blog.csdn.net/normanhere/article/details/138897203 版权
为了试验目的它展示了2种交换机的配置方法,以下是其中一种,N5K作为NPV模式,MDS交换机不需要指定端口速率模式,端口默认模式是trunk,允许所有VSAN DC2-MDS-1 feature npiv vsan database vsan 100 name vsan100 vsan 100 interface fc1/1 switchport mode F switchport trunk mode off no shut DC2-N5K-1 feature fcoe feature npv vsan database vsan 100 name vsan100 vsan 100 interface fc 1/31 interface fc 1/31 switchport mode np switchport trunk mode off no shut sho npv status ----------------------------- 以下是第二种配置方法,MDS交换机需要指定速率模式,端口模式为e DC2-MDS-1 vsan database vsan 200 name vsan200 interface fc1/5 switchport rate-mode dedicated switchport mode e switchport trunk mode on switchport trunk allow vsan 200 no shut DC2-N5K-2 feature fcoe vsan database vsan 200 name vsan200 interface fc1/31 switchport mode e switchport trunk mode on switchport trunk allow vsan 200 no shut sho int fc1/31 ------------------------------- 配置DC2-MDS-1 到 DC1-MDS-1链路 端口模式为e DC2-MDS-1 interface fc1/7 switchport rate-mode dedicated switchport mode e no shut 配置DC1-MDS-1交换机 vsan database vsan 100 name vsan100 vsan 200 name vsan200 exit interface fc1/7 switchport rate-mode dedicated switchport mode e no shut sho int fc1/7 ------------------------------------- 配置DC1-MDS-1 与 open-e互联口 DC1-MDS-1 vsan database vsan 100 interface fc1/10 vsan 200 interface fc1/11 interface fc1/10-11 no shut sho flogi database 查看注册信息 --------------------------------------- 配置esxi1与N5K-1和N5K-2互联口 端口模式需要改为F口 DC2-N5K-1 vsan database vsan 100 interface fc1/30 interface fc1/30 switchport mode f no shut DC2-MDS-1 : sho flogi database DC2-N5K-2 vsan database vsan 200 interface fc1/30 interface fc1/30 switchport mode f no shut sho flogi database ---------------------------------------- 配置 esxi2与DC2-MDS-1,注意这里只配置了1条链路是试验为了和esxi1做对比 DC2-MDS-1 vsan database vsan 100 inteface fc1/3 switchport mode f no shut sho flogi database ----------------------------------------- 在任意一台交换上 DC1-MDS-1配置ZONE,注意这一步不是必须,只是为了简化名称配置,只需要配置esxi和共享存储端口,中间交换机不管 device-alias database device-alias name esxi1to5k1 pwwn 21:00:00:1b:32:11:53:36 device-alias name esxi1to5k2 pwwn 21:01:00:1b:32:11:53:36 device-alias name esxi2tomds pwwn 21:00:00:1b:32:07:99:e7 device-alias name openefc10 pwwwn 21:00:00:1b:32:11:4d:33 device-alias name openefc11 pwwwn 21:01:00:1b:32:11:4d:33 device-alias commit zone name zone_vsan100 vsan 100 member device-alias esxi1to5k1 member device-alias esxi2tomds member device-alias openefc10 zoneset name zs_vsan100 vsan 100 exit zoneset activate name zs_vsan100 vsan 100 sho zone active zone name zone_vsan200 vsan 200 member device-alias esxi1to5k2 member device-alias openefc11 zoneset name zs_vsan200 vsan 200 exit zoneset activate name zs_vsan200 vsan 200 sho zoneset avtice vsan 200 ----------------------------------------- 接下来操作共享存储 open-e 光纤通道选择T模式;创建FC卷 ; FC目标管理器,创建卷组,添加卷;映射卷组到WWN 最后操作esxi 磁盘管理 指定为闪存类型;数据存储,添加存储;连接和多路径改成循环做路径高可用。 (责任编辑:) |